Schreiber-chillers Excellon MM30AC Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Schreiber-chillers Excellon MM30AC. Schreiber Chillers Excellon MM30AC User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
,
,
O
O
P
P
E
E
R
R
A
A
T
T
I
I
O
O
N
N
&
&
M
M
A
A
I
I
N
N
T
T
E
E
N
N
A
A
N
N
C
C
E
E
O
O
W
W
N
N
E
E
R
R
S
S
M
M
A
A
N
N
U
U
A
A
L
L
Model:
MICRO MAX 30AC
Serial No.:
Voltage:
230/1
Ref. Charge:
R134A
Tel: (562) 926-3855
Fax: (562) 926-0969
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Fax: (562) 926-0969

IINNSSTTAALLLLAATTIIOONN,, OOPPEERRAATTIIOONN && MMAAIINNTTEENNAANNCCEE OOWWNNEERRSS MMAANNUUAALL Model: MICRO MAX 30AC Serial No.:

Page 2 - CE RRITOS, CA 90703

SET POINT BUTTON TEMPERATURE DISPLAY INSIDE YOUR CHILLER Electrical System: • The controller is powered by 240 volt supply power as well as the

Page 3 - TABLE OF CONTENTS

Changing Set points: Setting cooling set point temperature: 1. Press the “SET” key, the symbol “SP” will appear to set desire cooling temperature u

Page 4 - ELECTRICALJ HAZARDS

SERVICE BULLETIN HERMETIC COMPRESSOR ELECTRICAL TERMINAL VENTING CAN BE DANGEROUS ****** When the insulating material, which supports a hermetic com

Page 5 - Specifications:

on Tecumseh Products Company drawings and diagrams using the parts as shown on Tecumseh Products Company bills of material. Hermetic compressors can

Page 6 - DO NOT USE DEIONIZED WATER!!

point if the leads are not properly removed, which can result in the terminal venting and hot oil discharging. No ignition, however, can occur if all

Page 7

protective device until you have located and corrected the problem. Refer to the Unit Wiring Diagram and Service Manual for the proper procedure and w

Page 8 - Model MICRO MAX series

MAINTENANCE INFORMATION 1. 2. There are no lubrication points on the chiller. All motors have permanent lubrication in the bearings. The water that

Page 9 - OPERATION

TROUBLE SHOOTING - PART I SYMPTOM DIAGNOSIS REMEDY Compressor won't run Check Power supply Electrical circuit Check Line load

Page 10 - Electrical System:

TROUBLE SHOOTING - PART II REFRIGERATION SYSTEM INTERNAL PRESSURE USING REFRIGERANT R-134A * High Pressure Switch : Manual Reset - Cut out at 425

Page 11 - Chilled Water System

30AC – 230/1 If this unit has special feature(s) installed, see appendix for part number(s). Part Number Description Qty. Refrigeration R30 1/3-H

Page 12 - SERVICE BULLETIN

SchreiberEng ineering12111 EAST PARK ST REETCE RRITOS, CA 90703TITLEMATERIALFINISHSCALE:DRAWING NO.DRAWN BY:DATE:REVDO NOT SCAL E D RAWING16 GA (.0

Page 13

(562) 926-3855 Schreiber Limited Warranty Schreiber warrants the product described herein against defective mat

Page 14

TABLE OF CONTENTS Model ………………………………….……………………………….….……………………….. 1 Table of Contents…………………….…………………………….……………………………... 2 Warning – Electr

Page 15

ELECTRICALJ HAZARDS1) TURNOFFMAIN POWERDISCONNECTSWITCHON THIS MACHINEBEFOREATTEMPTINGTOSERVICETHISEQUIPMENT.2) THIS MACHINEIS PORTABLE.DISCONNECTALL

Page 16

Specifications: GENERAL Max rated ambient temp. 95 °F Min. Chilled water temp. 44 °F Max Water Temp. 85 °F REFRIGERATION Refrigerant R134A Charge 1 l

Page 17 - TROUBLE SHOOTING - PART I

STARTUP CHECKLIST • POWER SUPPLY: Verify that the power supplying to the chiller matches the requirements as stated on the nameplate. Connecting chi

Page 18 - TROUBLE SHOOTING - PART II

8 9 10 111C1C1RModels:Voltage:Options:Schreiber Engineering12111 Park St. Cerritos, CA 90703(562)-926-3855(562)-926-0969 FaxPhase:Type: Air/Water Coo

Page 19

Schreiber Engineering – Air Cooled Water Chiller Model MICRO MAX series This unit is pre-wired for 230/1. To test unit as follows. ENSURE the s

Page 20 - Schreiber Limited Warranty

INSTALLATION 1. Place chiller on level ground. 2. Allow 3-in of clearance in the front and in the back of the unit. This clearance is necessary