Schreiber-chillers Excellon 150EX Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Schreiber-chillers Excellon 150EX. Schreiber Chillers Excellon 150EX User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 34
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
,
,
O
O
P
P
E
E
R
R
A
A
T
T
I
I
O
O
N
N
&
&
M
M
A
A
I
I
N
N
T
T
E
E
N
N
A
A
N
N
C
C
E
E
O
O
W
W
N
N
E
E
R
R
S
S
M
M
A
A
N
N
U
U
A
A
L
L
Model:
150EX
Part No.:
235785-02
Serial No.:
22297
Voltage:
460/3
Ref. Charge:
4.5 LBS R22
SCHREIBER ENGINEERING
a Division of DovaTech
12111 E. Park Street, Cerritos, CA 90703
Tel: (562) 926-3855 Fax:(562) 926-0969
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1 - SCHREIBER ENGINEERING

IINNSSTTAALLLLAATTIIOONN,, OOPPEERRAATTIIOONN && MMAAIINNTTEENNAANNCCEE OOWWNNEERRSS MMAANNUUAALL Model: 150EX Part No.: 235

Page 4 - ELECTRICALJ HAZARDS

Excellon 235785-01/02 CHILLED WATER DISTRIBUTION PIPING The chilled water distribution piping is an important factor in the performance of the wate

Page 5

Excellon 235785-01/02 INSTALLATION INSTRUCTION Air or Water Cooled Chillers 1. When the chiller is received, check for any shipping damage. If any

Page 6

Excellon 235785-01/02 necessary to check the rotation of the pump. The motors on all pumps have internal overload protection. 8. Power to the uni

Page 7 - /V'V\

Excellon 235785-01/02 1. Rotation of the water pump and fan motor must be correct. 2. Water in the tank must be at the proper level. 3. High tempe

Page 8 - ComQressor Switch - 0

Excellon 235785-01/02 The third control on the circuit is the manual compressor switch. It is only used to turn the refrigeration system on or off.

Page 9 - Exam)!les

Excellon 235785-01/02 The refrigeration system is a medium temperature system with a range from 350 F to 700 F. This is the most efficient range. If

Page 10

Excellon 235785-01/02 FAN MOTORS SPECIFICATIONS: H.P. 1/4 VOLTAGE - 220/230/460 3 phase HZ-50-60 RPM: 1725 OVERLOAD - Automatic, Intern

Page 11

Excellon 235785-01/02 2. InstallationInstallation, Operation and Maintenance Instructions.Model NP

Page 12 - Excellon 235785-01/02

Excellon 235785-01/02 TABLE OF CONTENTS Model …………………………………………………………………………………………..….. 1 Caution …………………………………………………………………………………………... 2 S

Page 13

Excellon 235785-01/02 2.3.2. Place unit in position on wedges located atfour points (two be

Page 14

Excellon 235785-01/02 6.1.1. Single-phase motor: Non-reversible. 6.1.2. Three-phase

Page 15

Excellon 235785-01/02 16

Page 16

Excellon 235785-01/02 WARNING Overcharging a refrigeration or air conditioning system can be dangerous. **** If a system refrigerant overcharge i

Page 17

Excellon 235785-01/02 SERVICE BULLETIN HERMETIC COMPRESSOR ELECTRICAL TERMINAL VENTING CAN BE DANGEROUS ****** When the insulating material, which s

Page 18 - FAN MOTORS

Excellon 235785-01/02 Hermetic compressors can be properly serviced without unnecessarily removing the terminal PROTECTIVE COVER by adhering to the f

Page 19 - Model NPE/NPE-F

Excellon 235785-01/02 9. If once again a ground is indicated, proceed to properly replace the compressor, as it has failed and cannot be repaired.

Page 20

Excellon 235785-01/02 Servicing refrigeration and air conditioning systems can be dangerous, and extreme caution in all respects should be exercised

Page 21

Excellon 235785-01/02 MAINTENANCE INFORMATION Part I 1. There are no lubrication points on the chiller. All motors have permanent lubrication in th

Page 22

Excellon 235785-01/02 MAINTENANCE INFORMATION Part II NOTICE ON EXPANSION VALVE This is a standard Alc

Page 23 - WARNING

~...SCHREIBER ENGINEERINGThe Finest Chiller Built in America.150AC--Wate r Chille r- SpecificationsQualitymattersTrnstt

Page 24

Excellon 235785-01/02 TROUBLE SHOOTING - PART I SYMPTOM DIAGNOSIS REMEDY Compressor won't run Check Power supply Electrical circ

Page 25

Excellon 235785-01/02 TROUBLE SHOOTING - PART II REFRIGERATION SYSTEM INTERNAL PRESSURE USING REFRIGERANT R-22 * High Pressure Switch : Manual Re

Page 26

Excellon 235785-01/02 CHILLER PARTS IDENTIFICATION 26

Page 27 - CRANK CASE HEATERS

Excellon 235785-01/02 PARTS LIST 235785-01: 230/3 or 235785-02: 460/3 If this unit has special feature(s) installed, see appendix for part number(s).

Page 28 - MAINTENANCE INFORMATION

Excellon 235785-01/02 28 Schreiber Limited Warranty Schreiber warrants the product described herein

Page 29

ELECTRICALJ HAZARDS1) TURNOFFMAIN POWERDISCONNECTSWITCHON THIS MACHINEBEFOREATTEMPTINGTOSERVICETHISEQUIPMENT.2) THIS MACHINEIS PORTABLE.DISCONNECTALL

Page 30 - TROUBLE SHOOTING - PART I

Excellon 235785-01/02 WATER CHILLER STARTING CHECKLIST PROPER VOLTAGE Check the voltage on the chille

Page 31 - TROUBLE SHOOTING - PART II

Excellon 235785-01/02 CONT. WATER CHILLER STARTING CHECKLIST ELECTRIC – POWER A good test to make sure

Page 32

L1L2L31WT1T2T3D. . ./V'V\r 1L1 L3T1T2T3Crank CaseHeaterPLUG EQUIPPED ON208/230 VOLTST1T2T3MYDOC/SCHREI BERIELECTRtCAUEXCELLON IS0AC24VHigh Temper

Page 33

INSTRUCTIONS FOR THE AMBIENTTEMPERATUE CONTROLLERTemperature Display -Labeled RESERVOIR Fo-0The temperature display can indicate three different input

Page 34 - Schreiber Limited Warranty

Exam)!lesIf the ambient air temperature is 75 degrees F and the reservoir temperature is 55 degrees F thecompressor will not start until the reservoir